top of page

Standing Seam - 1" Snap Lock Panel

1" Snap Lock Panel for Standing Seam
  • Low-Profile Architectural Standing Seam Metal Roofing System

  • Ideal for residential and light commercial applications

  • The specially designed clip allows thermal movement

  • Tested panel for rated assemblies achieves higher performance levels

1" Snap Lock Panel; max-width 16.89"; Snap Lock Seam fastened with (2) #10-12 x 1" long No. 2 Phillips drive pancake head, wood screws; One Part Clip Assembly SL100R Clip fastening metal to panel to minimum 15/32" plywood decking; maximum 24" clip spacing; Panel Rollformer: Schlebach Quadro-Plus Rollformer; Maximum Allowable Roof Uplift Pressure (steel): -67.3 PSF Main Field @ 24" Clip Spacing; Perimeter and Corner Pressure -131.0 PSF @ 6" Clip Spacing; Oil Canning is a characteristic of light gauge architectural metals and is not a flaw and therefore is not a cause for rejection.

1" Snap Lock Panel Standing Seam

Specifications

Design Information

Test Report Summary

• Minimum Slope = 3":12"

• Actual Panel Width: 16.89" from 20" Coil

• Solid Substrate Required

• Architectural, Hydrokinetic Panel

• Snap Seam – No Field Seaming Required

• 24 and 26 Gauge Galvalume®

• .032" Aluminum

• 16oz Copper

• 30 Year Finish Warranty on Kynar 500 Finish

• Weather Tight Warranty Not Available

• Underlayment Required

Miami Dade Building Code Compliance Approved

• Florida Building Code 2007

• Chapter 15: Roof Assemblies

• Section 1504.3.2; 1505.3; 1507.4

• Chapter 16: Structural Design

• Chapter 22: Steel; Section 2209 Cold Form Steel

• Chapter 23: Wood

• Testing per TAS 125-03 Std. Requirements for Metal Roof Systems

• Test Assembly #6 by Underwriters Laboratory for: a) UL 580-94, per FBC, Uplift Resistance of Roof Assemblies b) UL 1897-98, per FBC, Uplift Tests for Roof Covering Systems

• Testing per TAS 100 Wind Driven Rain Test

• FPA #9860.9 – HVHZ – 24ga

• M-D NOA #10-0603.09 - HVHZ - 24ga

bottom of page